Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT260005510

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Customer can not enter New Patient - Host computer cannot Acquire Scan Hardware, dataacq process is down. see Long Description for Error details Customer can not enter New Patient - Host computer cannot Acquire Scan Hardware, dataacq process is down. Errors: 260005510 Task 'dataacq' terminated prematurely Errors: 200002356 dataacq terminated unexpectedly, no action being taken. Errors: 200105002 Acquire of resource OC0:ScanAcqDev failed with status 1 Errors: 200350158 Can not acquire resource required for test

Error message

Error: 260005510 Process: dataacq Task 'dataacq' terminated prematurely Mon May 15 17:34:18 2006 Error: 260005510 Host: ct-vct Process: dataacq File: procDARC.cxx Line: 84 Task 'dataacq' terminated prematurely

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues