Pular para o conteúdo principal
GE Healthcare · CTLightSpeed260007770260007384

LightSpeed 4.X - GRE

Symptom

DAILY IQ CHECK THRESHOLD FAILURE

Error message

Error: 260007770 : Converter Board Broadcast Communication Error._ See long description for full error Error: 260007770 Converter Board Broadcast Communication Error. Communication timeout - no response. Tue Sep 28 13:32:37 2010 Error: 260007770 Host: orp Process: orp_subsys File: CnvBoardInterface.cc Line: 842 Tue Sep 28 13:32:36 2010 Host : Das Ermes # : 260007770 Exception Class : Secondary Severity : Pri/Soft File : CnvBoardInterface.cc Line# : 842 Function : No System Function Reported Scan Type : Scout Scan: 646/1/1 . Converter Board Broadcast Communication Error. See Following Error Message for Converter Card List Command: Calibrate Status

Error: 260007384 Scan ABORT -- DAS Has Detected An Error.^C The DAS has received an out-of-sequence command. Command 3000 cannot be accepted when the DAS is in the State: Normal State and Command Level: Scan in Progress Sat Dec 11 13:17:07 2004 Error: 260007384 Host: orp Process: orp_subsys File: invalcmd.c Line: 141 Sat Dec 11 13:17:06 2004 Host : Das Ermes # : 260007384 Exception Class : Abort Severity : Secondary File : invalcmd.c Line# : 141 Function : No System Function Reported Scan Type : Helical Scan: 1609/1/1 Scan ABORT -- DAS Ha

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2355552 MDAS 16 Convertor Card ( replaces 2322994-2 ) Used In LightSpeed 16 Gantry with MDAS. 2355552 MDAS 16 Converter Card used in LS 4X with 16 slice MDAS (replaces 2322994-2) Part #: 2355552 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.25 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: SERVICE, MDAS16 CONV BD FRU: Yes Status: Orderable Comments: Please consider ordering the used part when it is appropriate for your customer. It will save you substantial money. This is an MDAS16 CONV BD .compared to the SDAS. Make sure the correct Convertor is Ordered and replaced.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues