GE Healthcare · CTLightSpeedVCTBrightSpeed260118232503292601182895032726011821310153
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Error Reported when running the No-Load Kv test. Decoding 60-0316 errors. Error Reported when running the No-Load Kv test.
Error message
Error: 260118232 (60-1409)mAs meter saturated. See Long Description for complete error. Wed Sep 09/19/2007 16:48:50 Error: 260118232 Host: orp Process: jedi_subsys File: gen_exec.c Line: 2376 No System Function Reported Abort Severity : Primary Static Scan: 50329/1/1 (60-1409)mAs meter saturated. A check is done on mAs counter operation at the beginning of exposure and found the mAs meter with unrealistic value. Z6 ,Z7 = 0h,0h Error: 260118289 (60-0329) Wrong HV capacitance measured. See Long Description for complete error. Wed Sep 19 13:17:47 2007 Error: 260118289 Host: orp Process: orp_subsys File: gen_exec.c Line: 2376 Running diagnostic: kV and mA Test: Xray Functional Test Wed Sep 19 13:17:46 2007 Host : Jedi Ermes # : 260118289 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2376 Function : No System Function Reported Scan Type : Static Scan: 50327/1/1 (60-0329) Wrong HV capacitance measured. JEDI must be reset after KV Diags are performed. Error: 260118213 (60-0316) Spit Max error. PPC board has detected the number of tube spits during exposure has reached the limit See Long Description for two error examples Sat Dec 17 18:32:18 2005 Error: 260118213 H
Applies to
- Models
- LightSpeed, VCT, BrightSpeed
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required