Symptom
Customer gets Error message 'DAS gain calibration has not been run since converter boards were changed' while running fast cals. Customer gets Error message 'DAS gain calibration has not been run since convertor boards were changed' while running fast cals.
Error message
Error: 260001073 A Reset of the sub-system MUST be performed to continue See long description for full error Thu Jul 26 05:01:29 2007 Error: 260001073 Host: OBC Process: HOP File: hop node init.c Line: 389 Function: No System Function Reported Scan: 50233/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 05:01:26:960 Log Series: 49 Communications with the DCB have been re-established after being lost for unknow reason. A Reset of the sub-system MUST be performed to continue Error: 260004000 DAS firmware object: Lost communications with controller See Long Description for more details Wed Nov 22 05:44:35 2006 Error: 260004000 Host: OBC Process: DAS File: ss_comm.c Line: 329 Function: SYSTEM COMMUNICATIONS : Rotating Controller I/F Bus Scan: 50042/6/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 05:44:35:175 Log Series: 81 DAS firmware object: Lost communications with controller Error: 260002396 The DAS has received an out-of-sequence command Error: 260002396 Host: DAS Process: DCB Firmware Function: DATA ACQUSITION : Scan Data Acquisition Scan ABORT -- DAS Has Detected An Error.^C The DAS has received an out-of-sequence command. Command 3003 cannot be acce
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.