LightSpeed 5.X (60kW)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118362 Rotor Event Timestamps See Long Description for details Mon Jan 22 15:11:07 2007 Error: 260118362 Host: orp Process: orp_subsys File: gen_exec.c Line: 484 Mon Jan 22 15:11:06 2007 Host : On-Board Rotating Processor Ermes # : 260118362 Exception Class : Secondary Severity : Sec/Soft File : gen_exec.c Line# : 484 Function : No System Function Reported Scan Type : Axial Scan: 4987/2/1 Rotor Event Timestamps(mS) Cur Time: 956559655 Rx: 956559630 Active Scan: 0 ExpDly End: 956559630 Accel: 956507840 Run: 956466275 Accel Time: 6000 Decel: 956515840 Stop: 956516025 Decel Time: 185 No More Rx: 956555175 End Exam: 956146975 Error: 260118363 Rotor Timers See Long Description for details Mon Jan 22 15:11:07 2007 Error: 260118363 Host: orp Process: orp_subsys File: gen_exec.c Line: 494 Mon Jan 22 15:11:06 2007 Host : On-Board Rotating Processor Ermes # : 260118363 Exception Class : Secondary Severity : Sec/Soft File : gen_exec.c Line# : 494 Function : No System Function Reported Scan Type : Axial Scan: 4987/2/1 Rotor Timers Rotor Off Delay Rem(mS): 0 Rotor On Delay Rem(mS): 0 Filament Off Delay Rem(mS): 0 Filament On Delay Rem(mS): 0 Error: 260118177 Jedi (40-0114)Rotor not
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5128609-7 (replaces 5128609) Anode HV CABLE Used on HP60 and BrightSpeed Systems. Introduced April 2006 to correct thermal failure of 2241313-2 P9230TG High Voltage Anode cable See Long Description for details 5128609-7 HV cable - Anode Part #: 5128609-7 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: HV CABLE FRU: Yes Status: Orderable Old FRU Compatible No Comments Added per to ECR2115693 by 305024364 in April 7, 2011 Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5128609-7 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Direct ECO Number ECR2115693 Part #: 5128609 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: HV CABLE Positioning HP60 FRU: Yes Status: Orderable Comments: do not place new order for old p/n(2241313-2), existing old part should be used on HiSpeed Zx/i series only.
- Area
- CT