GE Healthcare · CTLightSpeed200002372
84546 LightSpeed 4.X
Symptom
System will not boot to or stay in applications. System will not boot or stay in applications
Error message
Error: 200002372 The process procICE took too long to start up. See long description for full error Tue Mar 30 15:07:53 2004 Error: 200002372 ct01 cupMonitor ssProcStart.c 839 The process procICE took too long to start up.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - Octane sw_version: 405I.2_H4.0M5 LightSpeed 4.X - Octane Gantry Model # 2339985 Console Model #'s 2341923 and 2341923-2(D3D) check_config shows LightSpeed 16 / LightSpeed 16 Product: LightSpeed16 sw_version: 405I.2_H4.0M5 or newer machine_type: Octane host_id: 3232297858 tube_type: 15 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2370825 RIP / Motorola Board, 2400 Series Card - replaces all previous part numbers - Oct 14 2004 See long description and attachment 2370825 RIP / Motorola Board, 2400 Series Card, replaces all previous part numbers - 10/14/2004 Part #: 2370825 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 9.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PPC MVME 2400 ASSY, HAWK3 U3D 256MB FRU: Yes Status: Orderable Comments: *** OBSOLETE PART *** This part has been identified as obsolete and no short-term solution has been identified. FE must identify and order a higher or lower level spare part as required. Contact your support engineer, on-line engineer or Parts ID team should you require support. 212012173 10-2-06 2/3/05 (212001261) New RIP-Bd 2370825 only works with LS2002M5 on LS 2X/3X & HS_QXi. LS 4X needs to run LS2002M5.1. To confirm what software version is running in the console, open a shell and type in check_config Even if the system is running LS2002M5, a LFC will probably be required. To determine if a LFC is required, open a shell and type in: showprods (the pipe symbol) grep Helios_MVME enter] if the prompt returns (Helios_MVME24XX_VxWorks_Product) where XX = any number, then no LFC, run pflash. If the prompt returns something else, LFC is required. GOC2/Linux-Pegasus are compatible with RIP-Bd P/N 2370825, (pflash) will need to be run. The following s/w versions support RIP Board 2370825: HS QX/I (IRIX) = 2401246 (101I.2_HSQXIM5), LS 2X (IRIX) 2395178 (2.4.2_H2.4M5); LS 3X (IRIX) = 2395177 (308I.2_H3.1M5), LS 4X (IRIX) = 5116050 (405I.3_H4.0M5.1), HS QX/I (Linux) = 2401245 (103L.4_HSQXIM4), LS 3X (Linux) = 2400882 (308L.5_H3.3M4), LS 4X (Linux) = 5111370 (405L.8_H4.2M4). Can order software via Coakly. Alejandro Cortez
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.