GE Healthcare · CTLightSpeedVCT26010721650145

Replace Axial encoder assembly, hub mounted wheel Used on H2-H5 and VCT

Symptom

Scan aborts. Scans abort

Error message

Error:260107216 Axial Motor Control (AMC) Logic detected Gantry (Axial) VELOCITY Failure. see long description Mon Apr 3 09:38:04 2006 260107216 4 tgp tgp_subsys amc_mon.c 968 Mon Apr 3 09:38:05 2006 Host : Table Gantry Processor Ermes # : 260107216 Exception Class : Abort Severity : Primary File : amc_mon.c Line# : 968 Function : AXIAL CONTROL : Axial Control Scan Type : None/Unknown Scan: 50145/1/0 Axial Motor Control (AMC) Logic detected Gantry (Axial) VELOCITY Failure. Measured: 0.519 sec/rev Commanded: 0.500 sec/rev HW/SW Error: Retry Rx to verify probable gantry hardware problem.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP, VCT, and HD750. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) See LD for details 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP and VCT. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) Part #: 5311936 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Shipping collector for Axial Encoder Assembly. FRU: Yes Status: Orderable Comments: Per ECR 2058601, 212008898, 10/8/08
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required