LightSpeed 4.X - GRE

Symptom

Reformats are going slow and are hanging up the software. See LD Reformats are going slow and are hanging up the software. Customer complaining that the Reformats are going slow as well as erratic mouse transition while they are running. Occassionally the software would seem to hang up.

Error message

Error: 245276 WARNING- Scan setup took 14721 ms on getting Cal Module. This could potentially cause scan timing issue or scan abort. See Long Description: Thu Apr 13 22:25:56 2006 Error: 245276 Host: ahi1 Process: scanmgr File: scanmgr_lib.cxx Line: 1197 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 319000 WARNING- Scan setup took 14721 ms on getting Cal Module. This could potentially cause scan timing issue or scan abort.

Error: 245274 WARNING- Scan setup took 3159 ms overall. See Long Description for more details Thu Mar 23 07:00:44 2006 Error: 245274 Host: fhtc2 Process: scanmgr File: scanmgr lib.cxx Line: 1322 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 17000 WARNING- Scan setup took 3159 ms overall. This could potentially cause scan timing issue or scan abort. Fri May 9 10:50:31 2008 Error: 245272 Host: ct01 Process: scanmgr File: scanmgr_lib.cxx Line: 1189 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 2779000 WARNING- Scan setup took 1897 ms on Step:7 (Get Cal Module).

Error: 230023004 Cal Processing TIMED OUT (360 Seconds). SEe LD for more details Thu Mar 23 06:54:34

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT