GE Healthcare · CTLightSpeedVCT26011816726011824150000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Unable to scan or perform tube warmup When the tube rotor spins up or down it may sound like a jet plane is landing and the gantry covers vibrate
Error message
Error: 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Wed May 12 13:54:03 2004 Error: 260118167 Host: orp Process: orp_subsys Wed May 12 13:54:02 2004 Host : Jedi Ermes # : 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Z6,Z7=7h,0h Code 40 Error code: 40-0104H Message/explanation: Rotation current open load Rotation board detected that no current is flowing to the motor. Potential cause: 1. Tube stator winding is open circuit: x-ray tube 2. Incorrect wiring (Open) 3. No DC bus on Rotation board 4. Phase shift capacitors not connected 5. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance ohm). If open circuit, replace tube. Check wiring from rotation board to tube. Check DC bus voltage present on rotation board. Troubleshoot cables and fuses from Pi Filter board to rotation board Check that phase shift capacitors are correctly connected Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board Error: 260118241 (80-0180) Rotation board communi
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2324118-3 VCT-JH4 Auxiliary Equipped. Aux Box See Long Description for details Part#:2324118-3 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT-JH4 AUXILIARY EQUIPED FRU: Yes Status: Orderable Comments: Set as Critical Part for Product CT_VCT, ms04278, 05Oct28 Added per VCT RSPL, ms13452 041205 Picture below
- Area
- CT