Defective Analogic RF amplifier.
Symptom
Unable to Scan with Analogic RF Amplifier Power Supply Faults 2238875 & 2238877 Unable to scan due to Analogic RF Amplifier Power Supply Faults as shown in Long Description Mon Jun 11 09:46:41 2007 Error: 2238875 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier Power Supply Fault. Analogic RF Amplifier indicates the main power supply is out of specification. Possible causes: Supply feedback loop exceeds specification, PS heat sink is overheated, Power supply FETS are shorted. Mon Jun 11 09:42:20 2007 Error: 2238877 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier I Peak Overloaded Fault. Line: 1621 Instantaneous peak drain current of RF devices exceeds specification.
Error message
2238877 Instantaneous peak drain current of RF devices exceeds specification. 2238877 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier I Peak Overloaded Fault. Line: 1621 Instantaneous peak drain current of RF devices exceeds specification. Error: 2238877 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier I Peak Overloaded Fault. Line: 1621 Instantaneous peak drain current of RF devices exceeds specification. 2238875 Analogic RF Amplifier Power Supply Fault. Analogic RF Amplifier indicates the main power supply is out of specification. Possible causes: Supply feedback loop exceeds specification, PS heat sink is overheated, Power supply FETS are shorted. 2238875 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier Power Supply Fault. Analogic RF Amplifier indicates the main power supply is out of specification. Possible causes: Supply feedback loop exceeds specification, PS heat sink is overheated, Power supply FETS are shorted. Error: 2238875 Host: MYMR3 Process: NSP File: HPC_PORT_ID:spi_rf_mon Line: 3068 Analogic RF Amplifier Power Supply Fault. Analogic RF Amplifier indic
Applies to
- Models
- Signa
- Product
- HF OpenSpeed HFO1 HFO2 and HFO3 Only.
- Software
- HFO3
- Component
- 2243079-2 0.7T RF POWER MODULE W/FRU CASE 0.7T RF POWER MODULE W/FRU CASE 2243079-2 0.7T RF POWER MODULE W/FRU CASE 2243079-2
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.