GE Healthcare · CTLightSpeedVCT26013480239872810000026013481611863450000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Table squeaks creaks scrapes is noisy when driven in or out of the gantry. Table squeaks creaks scrapes is noisy when driven is or out of the gantry.
Error message
Error: 260134802 IMS position is out of tolerance. See Long Description error messages Thu Oct 20 08:01:13 2005 Error: 260134802 Host: tgp Process: tgp subsys File: gtcb movechk.cxx Line: 581 Thu Oct 20 08:01:13 2005 Host : Table Sub-System Ermes # : 260134802 Exception Class : Secondary Severity : Pri/Soft File : gtcb movechk.cxx Line# : 581 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS position is out of tolerance. current position(um) : 398728 target position (um) : 0 start position (um) : 398728 velocity (um/s): 100000 time from start (ms) : 300 Error: 260134816 IMS velocity is out of tolerance. See Long Description for a complete error Fri Sep 22 09:51:38 2006 Error: 260134816 Host: tgp Process: tgp_subsys File: gtcb_velocity_chk.cxx Line: 295 Fri Sep 22 09:51:38 2006 Host : Table Sub-System Ermes # : 260134816 Exception Class : Secondary Severity : Pri/Soft File : gtcb_velocity_chk.cxx Line# : 295 Function : No System Function Reported Scan Type : None/Unknown Scan: 6856/5/0 IMS velocity is out of tolerance. current pos (um) : 118634 velocity tole(um/s) : 50000 expected vel (um/s) : 100000 current vel (um/s) : 47594 start pos (um) : -58 samp
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5168472-2 New style IMS bearing replacement kit for GT1700 or GT2000 tables. See long description for details Part #: 5168472-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: IMS DRIVE REPLACEMENT SET Positioning GT FRU: Yes Status: Orderable There is a new Kit for the VCT Table IMS. The old kit is no longer available. The old Kit part number will automatically change up to the number for the new kit: 5168472-2 . FE's are confused by the parts in the Kit and there are no installation instructions. FMI 26809 will be released with instructions: The Kit contains only one Bearing, but the Table has 2 Bearings. This is correct . The new Bearing is larger and as a result only one Bearing is required now. There are no instructions in the Kit on how to install all the parts. Use the hyperlink below to get instructions on how to install the Kit. http://jptyoiis01.ap.health.ge.com:8000/ctdoc/FMI/19/26809.pdf
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required