Def8000 Pasted image is stitched together from “sub-images” using a computer algorithm.
Revolution XQi, XRd, XRd 2X (Lightning) Platform & Definium Systems Image pasting misregistration
Symptom
Def8000 Pasted image is stitched together from “sub-images” using a computer algorithm. The stitched portion (overlap region) is marked by brackets “ [ ” on the side of the pasted image. See long description: One can check if the pasting registration is successful or not by visually looking anatomy in the stitched portions. Pasted images sometimes will be stitched together incorrectly, this is called “misregistration.” Misregistration can occur if: · The patient moved during an image pasting acquisitions. Our optimized pasting registration algorithm can overcome some small patient motion such as breathing. However, in most cases, large patient body motion can cause misregistration. · The patient position is incorrect. For instance, selected anatomy and view do not match the actual patient position. As the registration algorithm is done in a small feature searching boxes that are based on the selected anatomy view. · A patient is not positioned at the detector lateral center. · The collimator lateral FOV is too small, e.g., less than 10cm. In this case, the computer algorithm will not have enough anatomy to correctly stitch together. Misregistration should occur on less than 5 % of pasted images.
Applies to
- Models
- Revolution, Definium
- Product
- Revolution XRd2X Definium AMX 700 Revolution XQi Definium 8000 Revolution XRd
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- AEC Backup Time message
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.
- Definium 8000 One or both monitors display the following message on every boot
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.