GE Healthcare · X-ray R&FDefinium20004916001406490504
Def8000 Customer has intermittent problems with auto pasting.
Definium 8000 Auto Pasting Abort Problem
Symptom
Def8000 Customer has intermittent problems with auto pasting. The first exposure is made, the equipment repositions, but then they are not able to take the second exposure. Error log contains four distinct sets of errors for the four retry attempts the users made.
Error message
Error Auto Paste Abort See long description. Auto Paste Abort Error Log: 238,2006-08-24,12:53:32:115,"VEN",200049, Acquisition ended before all exposures completed,2222,WR,DEFAULT, SysCntrl, control, Cancelled Acquisition,1,1,1, EXPOSURE_ABORTED event while in STOP_SEQ,XRAcqSyncSM.cpp,258 239,2006-08-24,12:53:32:139,"VEN",200049, Acquisition ended before all exposures completed,2222,WR,DEFAULT, SysCntrl, control, Cancelled Acquisition,1,1,2, EXPOSURE_ABORTED event while in STOP_SEQ,XRAcqSyncSM.cpp,258 240,2006-08-24,12:53:32:181,"VEN",1600140, Aborting Image Processing for the specified frame ,2222,DO,DEFAULT, XRImProc, Constructor, 1. Retry the operation 2. Reset the operation and try again. 3. Call service if problem persists.,1,0,1, Aborting Sequence : 3,XRImProc.cpp,3818 241,2006-08-24,12:53:32:184,"VEN",1600140, Aborting Image Processing for the specified frame ,2222,DO,DEFAULT, XRImProc, Constructor, 1. Retry the operation 2. Reset the operation and try again. 3. Call service if problem persists.,1,0,2, Aborting Sequence : 3,XRImProc.cpp,3818 242,2006-08-24,12:53:32:259,"VEN",6490504, Expose command received without prep,2222,AR,DEFAULT, Pos, DeviceGroup, Retry. Reset the sys
Applies to
- Models
- Definium
- Product
- Definium 8000
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- AEC Backup Time message
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.
- Definium 8000 One or both monitors display the following message on every boot
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.
- Definium 8000 OTS Collimator has no power due to a tripped breaker (CB8) ont he Tube Suspension Logic (TSL) Board.
- Definium 8000 The Siemens Collimator has not power due to a tripped breaker (CB9) on the Tube Suspension Logic (TSL) Board.