Unable to Download SSFSE Scan Prescription due to ISE Backplane.
Symptom
Unable to Download SSFSE Scan Prescription Error The HPC watchdog has timed out See Long Description When downloading SSFSE, TPS hangs up with following error: ---------------------------------------------------------------------- 2224893 lx-mr NSP IPG_WDOG:hpc_wdog_task 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.) ------------------------------------------------------------------------------------------------ The problem is intermittent, occurring between once a week and once a month. But its frequency has been increasing lately. TPS power is OK. We've replaced the whole MEDCAM, the TPS CPU, TPS Bit3, Octane Bit3, UCERD, and IPG. PQR 13098746 SPR MRIhc22195.
Error message
2224893 The HPC watchdog has timed out Tue Jun 10 13:49:22 1997 Suite: MRS1 Host: OC0 Proc: IPG_WDOG Error: 2224893 File: PMH.m 1.29 Method: hpc_wdog_task Line: 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.) Tue Jun 10 13:49:22 1997 Suite: MRS1 Host: OC0 Proc: IPG_WDOG Error: 2224893 File: PMH.m 1.29 Method: hpc_wdog_task Line: 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.)
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- 2135974 ISE CHASSIS BACKPLANE
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.