Unable to Download SSFSE Scan Prescription due to ISE Backplane.
Symptom
Unable to Download SSFSE Scan Prescription Error The HPC watchdog has timed out See Long Description When downloading SSFSE, TPS hangs up with following error: ---------------------------------------------------------------------- 2224893 lx-mr NSP IPG_WDOG:hpc_wdog_task 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.) ------------------------------------------------------------------------------------------------ The problem is intermittent, occurring between once a week and once a month. But its frequency has been increasing lately. TPS power is OK. We've replaced the whole MEDCAM, the TPS CPU, TPS Bit3, Octane Bit3, UCERD, and IPG. PQR 13098746 SPR MRIhc22195.
Error message
2224893 The HPC watchdog has timed out Tue Jun 10 13:49:22 1997 Suite: MRS1 Host: OC0 Proc: IPG_WDOG Error: 2224893 File: PMH.m 1.29 Method: hpc_wdog_task Line: 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.) Tue Jun 10 13:49:22 1997 Suite: MRS1 Host: OC0 Proc: IPG_WDOG Error: 2224893 File: PMH.m 1.29 Method: hpc_wdog_task Line: 10 The HPC watchdog has timed out. Please see error log. WDOG timeout is caused by incorrect program execution and may be due to a hardware failure. (Could also try a different scan prescription, since the problem could be caused by a bad PSD.)
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- 2135974 ISE CHASSIS BACKPLANE
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.