Second acquisition after starting AUI causes Genieacq to lock up image display blanks out with message "Loading calibrat…
Second acquisition after starting AUI causes Genieacq to lock up image display blanks out with message "Loading calibration data", counts continue to update.
Symptom
Second acquisition after starting AUI causes Genieacq to lock up image display blanks out with message "Loading calibration data", counts continue to update. In some circustances the AUI would freeze completely, with no count or clock updates Second acquisition after starting AUI causes Genieacq to lock up image display blanks out with message "Loading calibration data", counts continue to update. Each time the software was started, the first scan would be acquired OK, but a second scan would stall after Camera On. The Start and Camera Off buttons were greyed out, but initially the count information and clock would continue updating and the user could also switch cards in the UI. Shutdown was blocked because a scan was in progress, so the only way to recover was to terminate the aui with <Ctrl><Alt><Backspace>. In some circustances the aui would go on to freeze completely, with no count or clock updates ELGem66790
Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Software
- GenieAcq R4.5 V14 (M4) Genieacq 4.5 Build 14 (M4) 5220379 Genieacq SW R4.5 V014 M4 with accumulative patches GA450-05-1, GA450-6-1, GA450-07-0, GA450-08-1, and GA450-09-0 for Spare Part GENIE Acq R 4.5 V014 supports EDI and I/N board hardware configurations. The following computer platforms are supported by this version: SuperMicro P4SBR ( only supports the EDI detctor, reference SN43628 ) IBM x205 Dell 1400SC Dell GX200 Dell 1300. Dell 2200 and Intel AltServer are not supported. Reference CIS 5150522-100_r2
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size