Pular para o conteúdo principal
GE Healthcare · MRSigna200608141450433226214504832298145132

CWA ID63040. Corrupt Image Database.

Symptom

Images are seen in the Browser, but Can't be Displayed. Message Box states "Browser Out of Sync with Database" See Long Description Customer suddenly couldn't display any images. He rebooted and began scanning again and can see images from current patient, but none from before the reboot. Cannot remotely list these images on the scanner using the "listselect" command.See a message "database is empty". The customer stated he sees a message "BROWSER OUT OF SYNC WITH DATABASE". There are no related errors logged in the message log, but there are a lot of "core file creation" errors logged in /var/log messages (see below) and related core files which have been written to /usr/g/service/log . The system can see the /export/home1 partition and a " df - k " command shows it is 26% full, but customer sees it is 30% full. Aug 14 14:50:43 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:50:43 S10MRIC dbrserver: program dbrserver: pid 6349: signal 11: file core.dbrserver.20060814.145043 Aug 14 14:50:48 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:50:48 S10MRIC dbrserver: program dbrserver: pid 32262: signal 11: file core.dbrserver.20060814.145048 Aug 14 14:51:32 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:51:32 S10MRIC dbrserver: program dbrserver: pid 32298: signal 11: file core.dbrserver.20060814.145132 Aug 14 14:52:20 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:52:20 S10MRIC dbrserver: program dbrserver: pid 32477: signal 11: file core.dbrserver.20060814.145220 Aug 14 14:54:44 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:54:44 S10MRIC dbrserver: program dbrserver: pid 32608: signal 11: file core.dbrserver.20060814.145444 Aug 14 14:58:33 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:58:33 S10MRIC dbrserver: program dbrserver: pid 441: signal 11: file core.dbrserver.20060814.145833 Aug 14 14:59:03 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:59:03 S10MRIC dbrserver: program dbrserver: pid 941: signal 11: file core.dbrserver.20060814.145903 Aug 14 14:59:16 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 14:59:16 S10MRIC dbrserver: program dbrserver: pid 1006: signal 11: file core.dbrserver.20060814.145916 Aug 14 15:00:21 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 15:00:21 S10MRIC dbrserver: program dbrserver: pid 1029: signal 11: file core.dbrserver.20060814.150021 Aug 14 15:00:43 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 15:00:43 S10MRIC dbrserver: program dbrserver: pid 1800: signal 11: file core.dbrserver.20060814.150043 Aug 14 15:01:03 S10MRIC dbrserver: dbrserver: CUP ERROR in file: cupMakeCore.c line: 329 Aug 14 15:01:03 S10MRIC dbrserver: program dbrserver: pid 1844: signal 11: file core.dbrserver.20060814.150103

Applies to

Models
Signa
Product
Signa LX Signa LX Product can be used with 8.x and 9.x systems.
Software
9.1 For Signa LX product only
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues