GE Healthcare · CTLightSpeed24504324517752400023000089550002245213

LightSpeed 5.X (80/100kW)

Symptom

Scan would immediately abort after bringing up rotor and pressing start scan light. See LD for details Scan would immediately abort after bringing up rotor and pressing start scan light. This problem has been reported to occur on occasion after Performing FMI 25365 Have also seen this after setting up to scan scout, axial or any type of data collection. The start scan light will light up and then the system will lose the DARC. The DARC will no longer be up at Linux level. Customer would then shut down the system and reboot, then the scenario would repeat.

Error message

Error: 245043 Scanning System Aborted Scanning. See LD for complete error Tue Feb 7 07:50:12 2006 Error: 245043 Host: ctscan1 Process: scanmgr File: scanmgr_events.cxx Line: 2115 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 1000 Scanning System Aborted Scanning

Error: 245177 An Acquition Complete event was recieved when Scan Manager was not in a scanning state. See LD for complete error Tue Oct 11 10:45:52 2005 Error: 245177 Host: er_ct5_vct Process: scanmgr File: scanmgr_events.cxx Line: 3531 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 524000 An Acquition Complete event was recieved when Scan Manager was not in a scanning state. Acq Complete Sequence Number: 524000

Error: 230000895 Scan Seq Id: #####View number sanity check failed: buffer number expected view number 1 actual view number 0 See Long Description for complete error: Error: 230000895 Scan Seq Id: XXXXXView number sanity check failed: buffer number expected view number 1 actual view number 0 Thu Apr 13 22:25:54 2006 Error: 230000895 Host: darc Process: dataacq File: dip_thread.cxx Line: 1422 Function: Data Acquisition : Scan Data Acquisition Sc

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.