Pular para o conteúdo principal
GE Healthcare · CTLightSpeed260107217260107210

LightSpeed 5.X (80/100kW)

Symptom

Gantry axial faults after performing the TGP to TGPU upgrade

Error message

Error: 260107217 axial motor control detected gantry motion without command See the Long Description for the full error code Wed Mar 23 10:01:01 2005 Host: Table Gantry Processor Ermes #: 260107217 Exception Class: Abort Severity: Primary File: amc_mon.c Line#: 1059 Function: AXIAL CONTROL: Axial Control Scan Type: Scout Scan: 1033/1/1 Axial Motor Control (AMC) Logic detected Gantry (Axial) MOTION without Command Current Position: 91.3 degs Commanded Position: 90.0 degs Degrees Tol: +/- 1 Retry Rx to verify probable Gantry Balance or Brake or Encoder Hardware problem

Error: 260107210 Gantry (Axial) Velocity OVERSPEED - Hardware Detection. Thu Dec 9 08:37:45 2004 Host: Table Gantry Processor Ermes# : 260107210 Exception Class: Safe State Severity: Primary File: amc_isr.c Line: 527 Function: AXIAL CONTROL : Axial Control Scan Type: None/Unknown Scan 0/0/0 Gantry (Axial) Velocity OVERSPEED - Hardware Detection. Measured Velocity: 0.999 sec/rev (Reference: 1000 AMC State: 8 AMC Cmd:21) Hdw Limit: 360 msec/rev HW Error: A RESET of the Scan Hardware is required and try again. Thu Dec 9 08:37:45 2004 Error: 260107210 Host: TGP Process: tgp_subsys File: amc_isr.c Line: 527 Running diagnos

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5370000 - TGPHD BOARD ASSY - TGPU For HD, HP and VCT (Replaces the 5271005-2 & 2349697-2, -3, -4 and -5). See Long Description about backward compatability. Part #: 5271005-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TGPHD BOARD ASSY Positioning VCTHD FRU: Yes Status: Orderable Comments: Per ECR 2098435, 212008898, 30 April 2010. Old FRU Compatible Yes Comments Per ECR 2098435, 212008898, 21 Jul 2010. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5271005-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number ECR2098435 2349697-5 is replacing the -4 version of this board. -3 versions are still in stock. If you are replacing parts in a VCT or HP gantry order the -3 until stock is depleted. ** FE ASSIST ** The 2349697-3 version is for VCT and all 5.x systems i.e. HP60 HP80- HP100's. The 2349697-4 version will works for CT750-HD and is backwards compatible but the -3 will not work on a CT750HD. (212001261 12/11/08) Part #: 2349697-5 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TGPU BD ASSY Positioning VCTHD FRU: Yes Status: Orderable Part #: 2349697-4 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: TGPU BD ASSY Positioning HD FRU: Yes Status: Orderable Comments: ** FE ASSIST ** The 2349697-4 is for CT750-HD and is backwards compatible to The 2349697-3 used on VCT and all 5.x systems i.e. HP60 HP80- HP100's. Do not use the 2349697-3 on CT750HD (212001261 12/11/08) TGPU 2349697-3 Part #: 2349697-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TGPU BD ASSY Positioning HP60 FRU: Yes Status: Orderable Comments: Added per VCT RSPL, this is replacement for -2, and non dash versions. ms13452 050325
Area
CT