GE Healthcare · CTLightSpeedVCT2601328022601327445009812793260122003
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260132802 The Data Acquisition System Has Detected An Over Temperature Condition. All Digital Module Power Has Been Disabled Until A Hardware Reset Is Performed See Long Description: Wed Dec 7 17:50:22 2005 Error: 260132802 Host: orp Process: orp_subsys File: IfbManager.cxx Line: 1697 Wed Dec 7 17:50:21 2005 Host : Das Ermes # : 260132802 Exception Class : Abort Severity : Primary File : IfbManager.cxx Line# : 1697 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 The Data Acquisition System Has Detected An Over Temperature Condition. All Digital Module Power Has Been Disabled Until A Hardware Reset Is Performed Error: 260132744 Digital Interface Board(s) Have Detected A Digital Module Has Exceeded The Maximum Temperature See Long Description Wed Dec 7 17:58:48 2005 Error: 260132744 Host: orp Process: orp_subsys File: Ifb.cxx Line: 504 Fri Mar 10 17:55:02 2006 Host : Das Ermes # : 260132744 Exception Class : Secondary Severity : Pri/Soft File : Ifb.cxx Line# : 504 Function : No System Function Reported Scan Type : None/Unknown Scan: 50098/4/0 Digital Interface Board(s) Have Detected A Digital Module Has Exceeded The Maximum Temperature DIFB : 26 Di
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required