GE Healthcare · CTLightSpeedVCT26013252350190260132486
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
DCB aborted the scan due to an Disruption in Das view Triggers across the Slip Rings. DCB aborted the scan due to an interruption of Das views across the Slip Ring
Error message
Error: 260132523 DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Thu Oct 5 06:53:14 2006 Error: 260132523 orp orp_subsys Acquisition.cxx 1478 Thu Oct 5 06:53:13 2006 Host : Das Ermes # : 260132523 Exception Class : Abort Severity : Secondary File : Acquisition.cxx Line# : 1478 Function : No System Function Reported Scan Type : Axial Scan: 50190/1/1 The DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Error: 260132523 DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This Typically Occurs Due to Slip-Ring Issues. Thu Oct 5 06:53:14 2006 Error: 260132523 orp orp_subsys Acquisition.cxx 1478 Thu Oct 5 06:53:13 2006 Host : Das Ermes # : 260132523 Exception Class : Abort Severity : Secondary File : Acquisition.cxx Line# : 1478 Function : No System Function Reported Scan Type : Axial Scan: 50190/1/1 The DAS Has Detected An Unexpected Gap In View Triggers. The Cause Is a Momentary Disruption In The Trigger Path. This
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required