GE Healthcare · CTLightSpeedVCT29001200126013246111026108151070010909
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Images report zero mA or 1999mA with noise in image or starved images See long description for picture of image and also IMPOSSIBLE ma readout Images report 0ma or 1999ma with noise in image or starved images Look at both pictures below!
Error message
Error: 290012001 There are more than XX consecutive bad views - no correction applied . . . exam/series/scan = XXX / XX / XXXX See LD for complete error Thu Feb 9 08:53:27 2006 Error: 290012001 Host: ig3 Process: image_generation File: MissedView.cpp Line: 910 View correction for view 9300 from views 9278, 9322 There are more than 21 consecutive bad views - no correction applied exam/series/scan = 345/4/1 Error: 260132461 Beam Tracking Detected Signal Corruption. See Long Description for more details Mon Oct 30 10:07:51 2006 Error: 260132461 Host: orp Process: orp_subsys File: Tracking.cxx Line: 523 Mon Oct 30 10:07:50 2006 Host : Das Ermes # : 260132461 Exception Class : Abort Severity : Secondary Function : No System Function Reported Scan Type : Helical Scan: 8935/200/1 Beam Tracking Detected Signal Corruption. mA Level: 0 Z Channels : 0, 11, 1, 4 Offset Vector: 11026, 10815, 10700, 10909 Or Mon Nov 13 11:26:59 2006 Error: 260132461 Host: orp Process: orp_subsys File: Tracking.cxx Line: 523 Mon Nov 13 11:26:58 2006 Host : Das Ermes # : 260132461 Exception Class : Abort Severity : Secondary File : Tracking.cxx Line# : 523 Function : No System Function Reported Scan Type : Helica
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.