GE Healthcare · CTLightSpeed26010720650180260107204
LightSpeed 5.X (60kW)
Symptom
Can not rotate gantry faster than 4 seconds
Error message
Error: 260107206 Axial Motor Control (AMC) logic will NOT accept commands until the Axial Drive is properly configured/initialized. See Long Description for full error Wed Apr 7 21:04:02 2004 Error: 260107206 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3771 Wed Apr 7 21:03:47 2004 Host : Table Gantry Processor Ermes # : 260107206 Exception Class : Abort Severity : Primary File : amc_mgr.c Line# : 3771 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Axial Motor Control (AMC) logic will NOT accept commands until the Axial Drive is properly configured/initialized. (Cmd: 27 Current State:0 Flags:0x8 ReInit Status:3). or Host : Table Gantry Processor Ermes # : 260107206 Exception Class : Abort Severity : Secondary File : amc mgr.c Line# : 3883 Function : No System Function Reported Scan Type : Axial Scan: 50180/1/2 Axial Motor Control (AMC) logic will NOT accept commands until the Axial Drive is properly configured/initialized. (Cmd: 21 Current State:0 Flags:0x8 ReInit Status:3) Error: 260107204 Axial Motor Control (AMC) logic could not configure the AXIAL drive via the CAN network during configuration. Reset scan hardware to retry. See Long Descript
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2217930-3 DRIVE ASSY, HPOWER AXIAL See LD for picture Part #: 2217930-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: DRIVE ASSY, HPOWER AXIAL Comments: FLS - DRIVE ASSY, HPOWER AXIAL USED ON CT LIGHTSPEED RT ADDED PER STARGATE RSPL MS13452 030927 RISK: SITE DOWN FREQUENCY: LOW REMOVED FROM STARGATE RSPL TO BE SUPPORTED AT LOWER LEVEL2235342-3 AXIAL MOTOR 2277225 BRAKE ASSY, 2233402 AX DRIVE MTR PDR REQUESTED IM05 REQUESTED FLS - FE NOTE: REMOVED FROM STARGATE RSPL TO BE SUPPORTED THRU LOWER LVL2235342-3 AXIAL MOTOR 2277225 BRAKE ASSY, 2233402 AX DRIVE MTR MS13452 031014
- Area
- CT