Can't Perform AFT due to Erbtec Faults 60, 61
Symptom
Unable to perform Erbtec AFT procedure in Head or Body mode See Long Description. Fault codes 60 during Head AFT and 61 during Body AFT appear on Erbtec display. These error codes appear on the Erbtec chassis' front panel display only, they do not get logged. Erbtec error code 60 decodes as follows: "IPA AFT does not converge; this indicates that sufficient power exists for AFT but the motors cannot force a zero-phase condition. Problems could exist with the motors, motor drivers, IPA phase detector, Processor Board A/D, IPA tube, or cabling". Erbtec error code 61 decodes as follows: "PA AFT does not converge; identical to fault 60 probable cause".
Error message
Erbtec 60 Fault IPA AFT does not converge This fault code appears on the Erbtec chassis' front panel display only, during AFT procedure. It is not logged. Erbtec fault code 60 decodes as follows: "IPA AFT does not converge; this indicates that sufficient power exists for AFT but the motors cannot force a zero-phase condition. Problems could exist with the motors, motor drivers, IPA phase detector, Processor Board A/D, IPA tube, or cabling." This fault code appears on the Erbtec chassis' front panel display only, during AFT procedure. It is not logged. Erbtec fault code 60 decodes as follows: "IPA AFT does not converge; this indicates that sufficient power exists for AFT but the motors cannot force a zero-phase condition. Problems could exist with the motors, motor drivers, IPA phase detector, Processor Board A/D, IPA tube, or cabling." Erbtec 61 Fault "PA AFT does not converge" Error code appears on the Erbtec display during Body AFT procedure. It isn't logged. The error decodes as follows: "PA AFT does not converge; identical to fault 60 probable cause".
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Component
- 46-305000P8 1.5T ERBTEC IPA INPUT BOARD 46-305000P8 1.5T ERBTEC IPA INPUT BOARD
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.