Need to acquire Genieacq Uniformity Correction file with more counts then the default of 30 Million.
Symptom
Need to acquire Genieacq Uniformity Correction file with more counts then the default of 30 Million. User is trying to change Genieacq Uniformity protocol to acquire a 120 Million count uniformity correction file. There is not a way to change the termination count at the user level in Genieacq software version below 4.0. Need to acquire Genieacq Uniformity Correction file with more counts then the default of 30 Million. User is trying to change Genieacq uniformity protocol to acquire a 120 Million count uniformity correction file. There is not a way to change the termination count at the user level in Genieacq software version below 4.0. Note: Genieacq software version 4.0 or above includes an addition to the AUI which now allows the operator to change the number of kcnts (from the default of 30,000) to 120,000 during the uniformity correction acquisition.
Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT
- Software
- Genieacq 2.7 Genieacq 2.7 Software Revision: Genieacq 2.7 Kit Part Number: FMI # / Service Note #: Comments: For MPT (MPS w/Single Axis Table). Not for MG, MC, MPR, MPS, IBACQ (400A), OptimaNX, IBx (X detector), or MyoSight. Genieacq 3.0 Software Revision: Genieacq 3.0 Build 16 Genieacq 2.5 Genieacq 2.5 build 15 Software Revision: Genieacq 2.5 Build 15 Kit Part Number: FMI # / Service Note #: FMI 40687 Comments: For MG, MC, MPR, MPS, IBACQ (400A), OptimaNX. Not for MPT, IBx (X detector), or MyoSight. Genieacq 4.0 Genieacq 4.0 Genieacq 3.1 Genieacq 3.1 Build 4 Genieacq 2.5.1 Genieacq 2.5.1 Software Revision: Genieacq 2.5.1 Kit Part Number: FMI # / Service Note #: Comments: For MG, MC, MPR, MPS, IBACQ (400A), OptimaNX. Not for MPT, IBx (X detector), or MyoSight. Genieacq 2.9 Genieacq 2.9 Software Revision: Genieacq 2.9 Kit Part Number: FMI # / Service Note #: Comments: For IBx (X detector). Not for MG, MC, MPR, MPS, IBACQ (400A), OptimaNX, MPT, or MyoSight.
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size