MVP3 Error 40 Voltage at Main Thyristor During Exposure
Symptom
MVP3 Error 40 Voltage at Main Thyristor during exposure. This error means that there is voltage at the Forced Commutation Main Thyristor during exposure, which is the equivalent of saying there is no exposure. This check is carried out from the time CLOSED LOOP signal is activated until the end of exposure. This error is considered FATAL for the system.
Error message
MVP3 Error 40 Voltage at Main Thyristor During Exposure See long description. The equipment should be switched off and when next switched on, in order to reproduce it again, another exposure should be initiated. Check whether any one of the thyristor control board LEDS corresponding to precontactor excitation is illuminated. Also check the precontactor current detection LED. If it is repeated, you should investigate the cause of the non-variation in level at pin P14 of the Forced Commutation Microprocessor U282. ONLINE CENTER COMMENTS AND TROUBLESHOOTING TIPS 1. On the Firing Board, observe LED DS175 (GMAIN) which indicates if the Main SCR Q2 is being turned on. 2. The Main SCR Q2 may be turning on, but has become resistive. There may still be voltage across it is turned on. 3. Replace the Main SCR Q2. Order as an assembly. The Main SCR has a press pak device. The correct pressure between the assembly plates is critical. If for any reason the FE has elected to order just the SCR and is reassembling the press pak, the correct torque on the two screws that hold the press pak together is reached when the tab in the center of the assembly is just free to move.
Applies to
- Product
- MVP 3 Phase
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- AEC Backup Time message
- New style ion chamber does not have a preamp
- Precision 500D Table Fluoro Carriage Front Bumper is not properly adjusted, allows excessive travel toward the front of the table.
- Precision 500D Aurora, dose readout does not update when an overhead Rad Tube Exposure is made, at any technic due to abnormally low mR/mAS from the Rad Overhead XRT.
- P500D Aurora with M4 Software (May 2006 Release), Dose Readout Correct on Console, Dose Printer Prints 0.0 due to a M4 Software Bug