GE Healthcare · CTLightSpeedVCT24527417000245272277900023001110050073

LightSpeed 5.X (60kW)

Symptom

Fastcals failed to complete. Fastcals failed to complete

Error message

Error: 245274 WARNING- Scan setup took 3159 ms overall. See Long Description for more details Thu Mar 23 07:00:44 2006 Error: 245274 Host: fhtc2 Process: scanmgr File: scanmgr lib.cxx Line: 1322 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 17000 WARNING- Scan setup took 3159 ms overall. This could potentially cause scan timing issue or scan abort. Fri May 9 10:50:31 2008 Error: 245272 Host: ct01 Process: scanmgr File: scanmgr_lib.cxx Line: 1189 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 2779000 WARNING- Scan setup took 1897 ms on Step:7 (Get Cal Module).

Error: 230011100 Unable to read a block of active views from a scan file on the scan data disks See LD for more details Tue May 23 07:14:38 2006 Error: 230011100 Host: ct01 Process: accs File: sdio_xfs_io_ops.c Line: 662 Function: CAL Processing : Data Restore Unable to read a block of active views from a scan file on the scan data disks. Error detected in read() call. Scan: CT01/50073/6/1 Bytes to read: c000h Starting offset: ef72000h Number read: 0h OS error : -1 --- Unknown error 4294967295

Error: 230019003 The scan disk I/O layer recieved a response fr

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
06MW03.5 For Pathfinder 1.5 ! NOT FOR VCT ! VCT uses 06MW03.4 06MW03.5 For Pathfinder 1.5 ! NOT FOR VCT ! VCT uses 06MW03.4 06MW03.5 For Pathfinder 1.5 Reboot BEFORE and AFTER detailed cals. Used on 1X/2X/3X/4X/5X, BrightSpeed & HS QX/i with GRE Consoles ! NOT FOR VCT ! VCT uses 06MW03.4 Reboot BEFORE and AFTER detailed cals This software was released with FMI 25365 in 2nd quarter 2006. 06MW03C.5 Class C Software (tab 182 distribution) Part # 5165729 06MW03M.5 Class M Software (tab 182 distribution) Part # 5154540 Training for this software (including Network Filters) can be found at http://data.supportcentral.ge.com/upload/25823/doc_1221870.pdf BrightSpeed S/W Information: You may see 06MW03.4 or 06MW03.5 loaded on BrightSpeed Systems. Why two different Versions? The story is when the program team released the BrightSpeed M3 Pilot sites in FW10 2006, 06MW03.5 (PF1.5 M3 version) was not ready, so the program team decided to use 06MW03.4 as BrightSpeed M3 version. When 06MW03.5 was released, BrightSpeed systems phased 06MW03.5 into the production line. The only difference between the two versions is the "Rotor not at speed" issue which was resolved in 06MW03.5. For BrightSpeed systems running 06MW03.4, a patch is needed to resolve the "Rotor not at speed" issue. The patch was shipped with all BrightSpeed systems running 06MW03.4. There is no reason to upgraded BrightSpeed systems running 06MW03.4 with the rotor patch installed. For systems running 06MW03.4 verify the rotor patch is installed: [insite@ct01 ~]$ showprods | grep -i patch I patch 04/10/2006 The GNU patch command, for modifying/upgrading files. ver 2.5.4 rel 2.5.4.19 I MX200ROTOR_PATCH 04/10/2006 This is a MX200 Rotor patch for 06MW03.* ver 1 rel 1.1 For 06MW03.4 the correct classC & classM: ClassC = part# 5167665 Ver 06MW03C.4 ClassM = part# 5167597 Ver 06MW03M.4
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues