GE Healthcare · CTLightSpeedVCT2601327870000040023000701450029230007011
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Concentric rings on images See Long Description for details Concentric rings on images
Error message
Error: 260132787 An ASIC Failed The Power On Reset Register Verification See LD for more details Tue Aug 29 05:17:28 2006 Error: 260132787 Host: orp Process: orp_subsys File: Ifb.cxx Line: 504 Tue Aug 29 05:17:47 2006 Host : Das Ermes # : 260132787 Exception Class : Secondary Severity : Pri/Soft File : Ifb.cxx Line# : 504 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 An ASIC Failed The Power On Reset Register Verification DIFB: 13 Digital Module: 27 ASIC Bitmap : 00000400 Error: 230007014 Uncorrectable detector channels have been found for scan See LD for an example of entire error message. Fri Oct 28 09:32:03 2005 Error: 230007014 Host: presbyplano Process: badchanmgr File: badchanmgr.cxx Line: 1194 Uncorrectable detector channels have been found for scan 50029/2/2 Error: 230007011 Density Check - Module (X) exceeds number of shorts allowed (X) = modual number See LD for complete error Mon Oct 31 07:03:37 2005 Error: 230007011 Host: cpcvct2p Process: badchanmgr File: DensityMap.cxx Line: 63 Density Check - Module 6 exceeds number of shorts allowed (151 > 64). Sat Aug 15 14:04:26 2009 Error: 230007011 Host: vct Process: badchanmgr File: DensityMap.cx
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5136400 FRDM Outer Digital Module Kit - VDAS-64 (IF NO STOCK order 5202049) Part #: 5136400 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: FRDM Detector Module Kit VCT64 FRU: Yes Status: Orderable Parts Offered as: Current: 5136400 Harvested: Not Available Exchange: Not Available Comments: ** FE ASSIST ** This is single outer VDAS64 Detector Module for field replacement (slots 1-26, 32-57 only). Order 5136400-3 for center slots. IF NO STOCK order 5202049 (July 22,2011) *** 2ND OPINION NOTES *** Run the maRatio test and verify the detector module is causing the issue. *** please refer to SN06101714b which recommends tightening the three torque screws for the flex connector to correct for open channels and send an email to [email protected] with results. (212001261 12/21/07) The FRDM handle is no longer in the kit. The handle is part of the DAS/Detector service kit sent with each system. If an FRDM handle is not available hold onto the digital cable screws to remove FRDM module This kit includes the following items: Part Number Description 5125342 FRDM Detector Module Assembly 5125344 Controlled Seating Tool 5134603 Bias Tool 5135869 FRDM Multi-tool 5122218 Spare Wedge Clamp 5116011 Spare Light Seal Clips 5136858 Torx Power Bit T20 2207303-6 Box of Nitrile Gloves, Large 2207303-7 Box of Nitrile Gloves, Extra Large 2269959 Large Blue Dissipate Lab Coat 5134848 Flange Socket M3x6 5151373 Hex Bit 2.5mm 5151374 Hex Bit 3.0mm Plus additional screw and washer hardware spares
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required