GE Healthcare · CTLightSpeedVCT290012001260132451260118320
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Images report zero mA or 1999mA with noise in image or starved images See long description for picture of image and also IMPOSSIBLE ma readout Images report 0ma or 1999ma with noise in image or starved images Look at both pictures below!
Error message
Error: 290012001 There are more than XX consecutive bad views - no correction applied . . . exam/series/scan = XXX / XX / XXXX See LD for complete error Thu Feb 9 08:53:27 2006 Error: 290012001 Host: ig3 Process: image_generation File: MissedView.cpp Line: 910 View correction for view 9300 from views 9278, 9322 There are more than 21 consecutive bad views - no correction applied exam/series/scan = 345/4/1 Error: 260132451 The Beam Tracking Algorihtm Encountered a Division by Zero Sat Sep 17 03:13:33 2005 Error: 260132451 Host: orp Process: orp_subsys File: Tracking.cxx Line: 542 Sat Sep 17 03:13:32 2005 Host : Das Ermes # : 260132451 Exception Class : Abort Severity : Secondary File : Tracking.cxx Line# : 542 Function : No System Function Reported Scan Type : Helical Scan: 542/2/1 The Beam Tracking Algorihtm Encountered a Division by Zero. Error: 260118320 E_EBL_IN line is disable. IO port D register bitmap. b8 See Long Description: Wed Jan 25 15:26:12 2006 Error: 260118320 orp orp_subsys gen_exec.c 3895 Wed Jan 25 15:26:10 2006 Host : On-Board Rotating Processor Ermes # : 260118320 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 3895 Function : No System Fun
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT