GE Healthcare · Nuclear MedicineMillennium
VG Collimator Cart is locked between detector heads, GDU displays HW error replace collimator to decoy
Symptom
VG Collimator Cart is locked between detector heads, GDU displays HW error replace collimator to decoy
Error message
VG Hardware error message, replace collimator to decoy VG Hardware error message, replace collimator to Error 34 occurs after VG Hardware error message, replace collimator to decoy VG Hardware error message, replace collimator or decoy Error 34 occurs after VG Hardware error message, replace collimator or decoy Error #34 (Error 34) CLC TASK SOFTWARE WATCH-DOG
Applies to
- Models
- Millennium
- Product
- VGH VG and VG Hawkey and Varicam
- Software
- VGH 6.0 VGH Acq 6.0 VG Acq 6.0 Part #: UGP001355 VG/DVG VER.6 KIT FOR SPARE PART (also see additional requirements below) Includes Software LSW000398 VG DVH HAWKEYE VER. 6 SW PACKAGE: Engineering Bill of Materials Name Description LSW000382 VG VH HAWKEYE Ver. 6 SW CD LSW000312 RCU for Dell 1400SC LSW000332 DISKETTE 1 SYSTEM LSW000403 Ver 6.0 Supplement 12 patch ver 6.0 build 7.5 (SN43633) LSW000426 VG Ver. 6 Motion and Worklist Patch.(SN43524) Also Includes: Software LSW000333 SOFTWARE PACKAGE FOR OLD COMPUTER VG: Engineering Bill of Materials Name Description LSW000011 DISKETTE 1 SYSTEM LSW000203 CKERMIT for GX200 LSW000022 SOFTWARE DELL ECU DISKETTE LSW000101 RCU for DELL 1300 ESW000637 HPC-HP 3COM LSW000404 DISKETTE 1 SYSTEM For HP NetServer Dell 2200 In addition VG requirements : UGP001583 VG Ver. 6.0 MUGA Patch LSW000490, FMI 40788 5195796 VG CoDe 2 Cold Spot, FMI 40805, CODE system only. 5169077 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633 Optional: 5169169 Service Pack # 5169169 Q3 ver 2.0, SN43632
- Component
- *Gantry Gantry Gantry
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size