GE Healthcare · CTLightSpeedVCT183124
LightSpeed 2.X (Plus, QX/i) - GRE
Symptom
Scanner would not scan on large or small filament
Error message
Error: 183124 FIL/MA fault detected: Inoperative filament inverter. See LD for more details Mon Aug 7 08:55:55 2006 Error: 183124 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 385 Function: XRAY GENERATION : Filament Selection Scan: 849/2/6 Type: Helical Exception Level: Pri/Most Severe Time: 08:55:55:030 Log Series: 632 FIL/MA fault detected: Inoperative filament inverter. Desired focal spot = 0. (0 = large, 1 = small) Fault latch address = ffdf4d hex, Bit = D7 Mon Aug 7 09:44:27 2006 Error: 183124 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 385 Function: XRAY GENERATION : Filament Selection Scan: 850/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 09:44:27:210 Log Series: 638 FIL/MA fault detected: Inoperative filament inverter. Desired focal spot = 1. (0 = large, 1 = small) Fault latch address = ffdf4d hex, Bit = D7
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 2.X (Plus, QX/i) - GRE always an SDAS 4 slice H2_P_S4 (SDAS4 and H2 gantry) Lightspeed 2.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 3.X and 4.X. Always has an SDAS 4 slice Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2154834 MA Board used on (CT/i,1.X-4.X) scanners See Long Description for more Part #: 2154834 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 1.81 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MA CONTROL BRD./CANCEL FRU: Yes Status: Orderable Comments: FLS - MA BOARD USED ON FAST RHAPSODE FMI#25238 UPGRADES THIS BD. TO A REV.1 ONE USE LIGHTSPEED ULTRA HQT WARNING!! MATERIAL MUST BE PURCHASED FROM MFGING DO NOT GO TO VENDOR AS IT MUST BE TESTED IN MFGING BEFORE SHIPPED TO FIELD VERY VERY HIGH DOA RATE. MS08992 GVR 7/31/00GELS
- Area
- CT
Full cause & step-by-step resolution