LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

During hardware reset, RED popup Windows message appear: "One or more Function controllers TGP/ORP/JEDI/DCB/CCB has detected an error. Please try Flash download to clear this error". See LD for more details During hardware reset, the Scan Monitor displays a RED Window with a message "One or more Function controllers TGP/ORP/JEDI/DCB/CCB has detected an error. Please try Flash download to clear this error". After clicking the OK another window is displayed stating "Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. GE Medical Systems cannot assure that the system performance will conform to specifications" Flash download runs but it does not change the symptoms.

Error message

Error: 244649 The Smart ID status See LD for full error plus the various codes and what they mean. Wed Jun 28 09:30:00 2006 Error: 244649 Host: ct99 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 460 The Smart ID status is 1 . (See below for other possible codes!) SmartID status options are: 0 => Scanner hardware not available - LFC value 1 => No Smart ID board on tube <==== Could be GE tube without the ID, non GE tube, or broken 2 => Smart ID board fails the secret handshake <=== It is broken 3 => Valid Smart ID board on tube <===== This is normal and means there is no problem.

Error: 260132795 The Following Digital Modules Have An B-Side A/D Board Error. See Previous Messages From Last Reset For Detailed Fault Information. See LD for the full message. Wed Jun 28 09:29:25 2006 Error: 260132795 Host: orp Process: orp_subsys File: IfbManager.cxx Line: 338 Wed Jun 28 09:29:23 2006 Host : Das Ermes # : 260132795 Exception Class : Abort Severity : Secondary File : IfbManager.cxx Line# : 338 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 The Following Digital Modules Have An B-Side A/D Board Error. See Previous Messages From Last Reset For Detailed Fau

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5955048 (eqvt part 5151006, 5113710) VCT DIFB Digital Interface Board - Sherlock detector See long description for details. Part #: 5955048 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT DIFB PWA FRU: Yes Status: Orderable Parts Offered as: Current: 5955048 Harvested: Not Available Exchange: Not Available Comments: Per GEC-to-Flextronicw transfer program and ECR 2104697, 212008898, 24 Aug 2010. Old FRU Compatible Yes Comments Per GEC to Flextronics Transfer Program #020000, 212008898, 8 Sept 2010. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5955048 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number BOK39368 Old FRU Compatible Yes Comments Per GEC to Flextronics Transfer Program #020000, 212008898, 8 Sept 2010. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5151006 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number BOK39368 5151006 (eqvt part 5113710) VCT DIFB Digital Interface Board - Sherlock detector Part #: 5151006 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT DIFB PWA FRU: Yes Status: Orderable ** FE ASSIST ** If no stock can use P/N 5113710 (212001261 10/12/07) Part #: 5113710 Part Type: GP CONSUMABLES Part Weight: -90719.09 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT DIFB FRU: Yes Status: Orderable ** FE ASSIST ** If no stock can use P/N 5151006 (212001261 10/12/07)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.