Scanner Hardware Stopped Scan message during axial scan
Symptom
Scanner Hardware Stopped Scan message during axial scan. Long Description for Feedback Only. Scanner Hardware Stopped Scan message during axial scan
Error message
Error: 183296 Monitoring: (Measured 245.5 mA vs Ref 240 mA) See Long Description for the full error Error: 183296 Suite: CT01 Host: OBC Process: Generator File: gen_tech.c 1.36 Method: No Method Line: 529 Function: No System Function Reported Scan: 65001/8/38 Type: Axial Exception Level: Sec/Soft Time: 03:11:20:495 Log Series: 49 Selected Technic: 100 kV, 240 mA, 0 % Mod, Backup Timer 4324. VarmA: (Index: Start 0, Skip 0, Last 0) Last Cmd 240 mA. Monitoring: (Measured 245.5 mA vs Ref 240 mA) . 5 Total Samples, Tube Spit Ctr 0. (Rotor 0x0000ae04, Gen 0x9c19b5ff, Mon 0x00020000 Error: 183105 KV fault detected: Anode overvoltage. Anode kV > 82kV. See LD for error example Thu Sep 16 11:15:54 2004 Error: 183105 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 210 Function: XRAY GENERATION : KV Loop Scan: 50005/9/13 Type: Axial Exception Level: Pri/Most Severe Time: 11:15:55:750 Log Series: 373 KV fault detected: Anode overvoltage. Anode kV > 82kV. Fault latch address = ffcff3 hex, Bit = D0 Error: 183183 kV out of 3 % tol See Long Description for error example Error: 183183 Suite: CT01 Host: OBC Proc: Generator File: gen tech.c 1.32 Method: No Method Line: 791 Function: XRAY G
Applies to
- Models
- HiSpeed, LightSpeed
- Product
- HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2122960 COMMON INVERTER HSA / RP-EMC FOR ANODE OR CATHODE (CTi Inverter) 2122960 COMMON INVERTER HSA / RP-EMC FOR ANODE OR CATHODE (CTi Invertor) 2122960 COMMON INVERTER HSA / RP-EMC FOR ANODE OR CATHODE (CTi Inverter) Part #: 2122960 Part Type: GP REPAIRABLES Part Weight: 30.86 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: COMMON INVERTER FRU: Yes Status: Orderable
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.