GE Healthcare · CTLightSpeed230023041230023004

40268 After Fast Cal completes software begins a Z-Slope Calibration Test.

Symptom

After Fast Cal completes software begins a Z-Slope Calibration Test. See long description for details After Fast Cal completes software begins a Z-Slope Calibration Test. Screen states Generating Cal vectors, May Take 4 Minutes but the test does not complete.

Error message

Error: 230023041 Found the Zslope cal vectors are already 6 month old and need to update See the Long Description for the full error code Mon Oct 17 23:58:54 2005 Error: 230023041 Host: cts1 Process: dailyPrepRx File: DailyPrepUtils.c Line: 4394 Found the Zslope cal vectors are already 6 month old and need to update

Error: 230023004 Cal Processing TIMED OUT (360 Seconds). SEe LD for more details Thu Mar 23 06:54:34 2006 Error: 230023004 Host: fhtc2 Process: dailyPrepRx File: DailyPrepUtils.c Line: 774 Cal Processing TIMED OUT (360 Seconds). Please hit Resume to try again.

Applies to

Models
LightSpeed
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
05MW14.5 for all systems with GRE/Xtream consoles on HiSpeed QX/i and LightSpeed 1.X, 2.X, 3.X, 4.X, 5.X Series(QXi, PLUS, ULTRA, LS16, PRO 16, RT). Obsoleted by FMI 25365 deploy FMI 25365 It is the Service person's responsibility to use the appropriate documentation when performing and verifying service. Refer to FMI 25365: 06MW03.5 SW Update for CT-LS 1X/2X/3X/4 DIR 5161945-100, which can be found on the Distributed Technical CDROM/DVD, or online Links to any needed documentation is found in the Product concepts as an attachment called "ProductDocumentLinks"
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required