GE Healthcare · CTLightSpeed2600010301646126000101226000107516458
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Scanner hardware reset and flash download fails
Error message
Error: 260001030 The DCB application code is not loaded. See LD for more details Error: 260001030 The DCB application code is not loaded. Fri May 19 12:33:23 2006 Error: 260001030 Host: OBC Process: HOP File: hop_misc.c Line: 315 Function: No System Function Reported Scan: 16461/2/0 Type: None/Unknown Exception Level: Secondary Time: 12:33:22:955 Log Series: 540 The DCB application code is not loaded. Scanning is disabled. Load application code and reset sub-system. Node status code: 0x8381 State flag: 0x1801680 Error: 260001012 The Rotating Controller Interface Bus (RCIB) fault line has been asserted See Long Description for the full error code Sat Jun 9 14:37:06 2001 Error: 260001012 Host: OBC Process: HOP File: hop_fault_state.c Line: 137 Function: No System Function Reported Scan: 9553/3/1 Type: Axial Exception Level: Pri/Most Severe Time: 14:37:06:030 Log Series: 366 The Rotating Controller Interface Bus (RCIB) fault line has been asserted. None of the sub-systems have reported a problem. Check nodes or fault line for failure. Error: 260001075 The SRU has failed to send a FLASH verification message for the DCB. See LD for more details Error: 260001075 The SRU has failed to s
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2225218 DCB HOUSING ASM for SDAS See LD for details Part #: 2225218 Part Type: GP REPAIRABLES Part Weight: 0.66 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: DCB HOUSING ASM (SDAS) FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2225218 Harvested: Not Available Exchange: Not Available Comments: FLS - DCB ASM, P/N 2225218 7/31/02- C2R COMPLETED PER M DIGGINS, CHANGE ORDER TO T3202KJ BEFORE SHIPPING. MS12464 CAN'T ORDER DAS ASSY SEE T3202KJ 1/2/02 VEN HAS 20 PC MINIMUM BUY PER PO AND 60 DAY LEAD TIME. MS09121 *** CD & S NOTE **** BEFORE REPLACING THE SDAS DAS CONTROL BOARD (DCB), MEASURE THE +5V ON THE BOARD FROM TP-1 - TP-2. VERIFY THIS IS ABOVE4.8 VOLTS. VOLTAGE LOWER THANTHIS MAY CAUSE INTERMITTENT OPERATIONS. IF THE VOLTAGE ISOK ON THE CONVERTER CARD CHASSCHASSIS, YOU MAY HAVE A CABLE PROBLEM. MS30863 5/31/02 GELS - CSO0111459 FRANCE F-45071720002 /04/01/TS FIBER OPTIC FREQ 50 MHZ / NEEDS DIP BOARD 2275604 OR 2245261 PDB 02/01/21,DCB HOUSING ASM
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required