Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT290012001260132451290009001

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Images report zero mA or 1999mA with noise in image or starved images See long description for picture of image and also IMPOSSIBLE ma readout Images report 0ma or 1999ma with noise in image or starved images Look at both pictures below!

Error message

Error: 290012001 There are more than XX consecutive bad views - no correction applied . . . exam/series/scan = XXX / XX / XXXX See LD for complete error Thu Feb 9 08:53:27 2006 Error: 290012001 Host: ig3 Process: image_generation File: MissedView.cpp Line: 910 View correction for view 9300 from views 9278, 9322 There are more than 21 consecutive bad views - no correction applied exam/series/scan = 345/4/1

Error: 260132451 The Beam Tracking Algorihtm Encountered a Division by Zero Sat Sep 17 03:13:33 2005 Error: 260132451 Host: orp Process: orp_subsys File: Tracking.cxx Line: 542 Sat Sep 17 03:13:32 2005 Host : Das Ermes # : 260132451 Exception Class : Abort Severity : Secondary File : Tracking.cxx Line# : 542 Function : No System Function Reported Scan Type : Helical Scan: 542/2/1 The Beam Tracking Algorihtm Encountered a Division by Zero.

Error: 290009001The scanfile does not have enough views to make requested images. See LD Error: 290009001The scanfile does not have enough views to make requested. Tue Dec 6 11:07:48 2005 Error: 290009001 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 2684 The scanfile does not have enough views to make requested images. exam

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5120819-2 RoHS Compliant Slipring Brushblock Assembly used on 5.X-7.X gantry. replaces 2349598 5120819 See long description for details 5120819-2 RoHS Compliant Slipring Brushblock Assembly Old FRU Compatible Yes Comments Per ECR 2087298, 212008898, 8/5/09. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5120819-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number ECR2087298 Part #: 5120819 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT Slipring Brushblock. Same as Hpower, but has additional voltage creepage distance for 208VAC. FRU: Yes Status: Orderable Comments: Added per ECR 2011062 new VCT Brushblock (5120819) on sliprings 2320265 and 2364819. Also added by VCT NPI RSPL UPDATE, ms13452 050916.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues