Unable to scan due to PSD Errors.
Symptom
Unable to scan due to PSD Errors. Scan abort occurs. (See long description for scan Rx this occurred on). Tech sees an operator message: "A PSD error occurred. See log." These errors are found in the log (note: FSE Optimization was NOT turned on). PATIENT INFORMATION SCREEN Weight (kg) :72.6 Rx Level :SERIES Rx Mode :ACTIVE Scanner Mode :CLINICAL PATIENT POSITION SCREEN Entry :FEET Position :SUPINE Coil Type:SURFACE Scan Plane:AXIAL Landmark :1089.800 Protocol :MR CHOLANGIOGRAM Series De:AXIAL MR CHOLANG IMAGING PARAMETERS SCREEN Image Mode :2D Pulse Seq :SPIN ECHO Image Options:NPW, VBw, EDR, TRF, Fast SCAN TIMING SCREEN Echo Train Length:16 Number of Echoes :1 Echo Time (TE) :240.0 Rep Time (TR) :5000.0 SCAN SETUP SCREEN Auto CF :WATER Prescan Options:PhCor RBW :15.6 kHz SCANNING RANGE SCREEN Field of View :36 cm Scan Thickness :3.0 mm InterScan Spacing:0.0 mm Start Loc :L-0.0 P-0.0 I16.0 End Loc :L-0.0 P-0.0 S104.0 No. Scan Locs :41 SATURATION PARAMETER SCREEN SAT Pulses :S, I Supress Tech :NONE ACQUISITION TIMING SCREEN Acq. Matrix :256 X 256 Scan Time :11:59 # Acquisitions:2 NEX :4.00 Freq. Dir :A/P Locs B4 Pause :0 Contrast :No GENERAL INFORMATION Est. Ave. SAR :0.69 Est. Peak SAR :1.38 dB/dt Limit : 70%
Error message
2218527 Scanning has stopped. not enough memory available to start acquisition, please try again. 2218527 Host: MR_MT305 Process: scn File: MsaScanOpsScrn.m Line: 909 Scanning has stopped. not enough memory available to start acquisition, please try again. Error: 2218527 Host: MR_MT305 Process: scn File: MsaScanOpsScrn.m Line: 909 Scanning has stopped. not enough memory available to start acquisition, please try again.
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.