GE Healthcare · CTLightSpeed215520129306
LightSpeed 4.X - GRE
Symptom
Rotor does not spin up and HVDC Voltage has dropped below the operating level. See long description Rotor does not spin up and the HVDC Voltage has dropped below the operating level.
Error message
Error: 215520 The rotor control board detected the HVDC Bus has dropped below the operating level . No tests were being run .Register address: FFB829H Bit: D2 value : 1 See LD for complete error Wed Mar 22 07:46:31 2006 Host: OBC Proc: Diag Exec. Error: 215520 File: isrt_handler.c 1.39 Line: 821 Function: DIAGNOSTICS SYSTEM MONITORING : HVDC Monitor Test Name: No Test Name UniqueID : 0 Iteration : 0 Exec. Level: Hard Time : 129306 Error Type : Hardware The rotor control board detected the HVDC Bus has dropped below the operating level . No tests were being run . Register address: FFB829H Bit: D2 value : 1
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required