Unable to complete a coronal oblique T1 scan due to miniGRAM OverVoltage Fault
Symptom
Unable to complete a Coronal Oblique T1 scan due to miniGRAM OverVoltage Fault The customer is having a problem with this protocol only. But they have rebuilt the protocol with no change to symptoms. The FE initially thought it was an intermittent problem until he found out that it always happens when the angle of obliquity is set to exactly 270 degrees. If they set it to 269 or 271 degrees, it doesn't happen. The FE tried replacing the miniGRAM and the GIP without resolving the problem.
Error message
2241544 The gradient system on the Z axis recovered successfully. Mon Jun 25 23:45:29 2001 Error: 2241544 Host: lx-mr Process: NSP File: HPC_PORT_ID:GAP/GIP Line: 1342 The gradient system on the Z axis recovered successfully. There are no faults at the present time. 2241526 The miniGRAM Power Supply failed to go to Ready when commanded, or came out of Ready 2241526 HSC_MR01 NSP HPC_PORT_ID:GAP/GIP/GP 2481 The miniGRAM Power Supply failed to go to Ready when commanded, or came out of Ready. Possible causes: cable between GIP & miniGRAM Power Supply, the miniGRAM Power Supply, or the GIP. 2241515 The GIP reported a Z Axis miniGRAM OverVoltage Fault. 2241515 HSC_MR01 NSP HPC_PORT_ID:GAP/GIP/GP 2092 The GIP reported a Z Axis miniGRAM OverVoltage Fault. Try swapping the miniGRAM Control Board, or the entire miniGRAM axis, or the miniGRAM Power Supply to isolate the problem.-> 2234211 MR Signal too large. Reduce Receive Gain 1. See Long Description Error: 2234211 Host: MR1SMR Process: NSP File: TPS:asc_check_RAP_overrange Line: 206 MR Signal too large; Reduce Receive Gain 1.
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.