GE Healthcare · CTLightSpeed18480235462178517
35115 LightSpeed 4.X
Symptom
Can't do tube warm up and no flashing eights on gantry display
Error message
Error: 184802 Communication Facility Error: 2103 Dest uuid: 0 Msg Code: 7021 See LD for complete error Fri Mar 10 10:50:32 2006 Error: 184802 Host: ETC Process: Table Controls File: tc_exec.c 1.27 1/15/96 Line: 219 Function: No System Function Reported Scan: 35462/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 10:50:32:880 Log Series: 267 Communication Facility Error: 2103 Dest uuid: 0 Msg Code: 7021 Error: 178517 Failure writing to socket connected to controller STC/OBCR/ETC. No route to host See Long Description for variations Fri Oct 8 07:49:17 2004 178517 ct03 fwmgr NBSSocket.c 690 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Failure writing to socket connected to controller STC. OS error : 113 --- No route to host Fri Oct 8 07:49:13 2004 178517 ct03 fwmgr NBSSocket.c 690 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Failure writing to socket connected to controller OBCR. OS error : 113 --- No route to host Fri Oct 8 07:49:33 2004 178517 4 ct03 fwmgr NBSSocket.c 690 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Failure writing to sock
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2266880-2 PDU to gantry 120VAC 3 phase power cable See LD For details P/N 2266880-2 PDU to gantry 120VAC 3 phase power cable Part #: 2266880-2 Part Type: Not Available Part Weight: 0.00 LBR Repairable: Not Available Returnable: Not Available Hazardous Material: N Description: Not Available FRU: No Status: Non Orderable
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required