LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner prevents tube warm up or Fastcals for 55 minutes every morning See LD for more details Scanner prevents tube warm up or Fastcals for 55 minutes every morning and posts Error: 260002451 Detector Temperature Is Low. Image quality may be affected.

Error message

Error: 260002451 Detector Temperature Is Low. Image quality may be affected. See LD for complete error Thu Aug 25 16:32:02 2005 Error: 260002451 Host: DAS Process: DCB Firmware File: dtemptst.c Line: 362 Function: DATA ACQUISITION : Detector Heater Scan: 50048/6/44 Type: Axial Exception Level: Pri/Soft Time: 16:32:02:230 Log Series: 56 Detector Temperature Is Low. Image quality may be affected. Current Reading:25.61 Deg C A/D Counts:11102

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT