GE Healthcare · CTLightSpeedVCT26010011050070245043
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
"Scan hardware Stopped Scan" with PDU errors "Scan hardware Stopped Scan" with PDU errorss
Error message
Error: 260100110 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0. -OR YOU MAY SEE- The PDU Kss Contactor has NOT closed in the alloted time. Timeout:300 msec Timer:0 msec Contactor Status: Open Error: 260100110 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0.Tue Jul 27 18:25:12 2004 Error: 260100110 [insite@hvllct01 ~]$ /usr/g/insite/bin/viewlog Host: tgp Process: tgp subsys File: scHvdcMgr.c Line: 307 Tue Jul 27 18:25:13 2004 Host : Table Gantry Processor Ermes # : 260100110 Exception Class : Abort Severity : Primary File : scHvdcMgr.c Line# : 307 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Scout Scan: 4949/1/1 HVDC KSS Contactor is NOT Closing based on the Relay Status. Timemout:2000 msec Status:0. This error is flagged by Table Gantry Processor on the SYSTEM MONITORING : HVDC Monitor. ---------Similar error below but for Axial Scan------------ Tue Feb 7 07:50:11 2006 Error: 260100110 Host: tgp Process: tgp_subsys File: scHvdcMgr.c Line: 328 Tue Feb 7 07:50:11 2006 Host : Table Gantry Processor Ermes # : 260100110 Exception Class : Abort Severity : Primary File : scHvdcMgr.c Line# : 328
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2334820-3 replaces 2334820-2 PDU control board Used by BSD,HD,VCT, RT,LS,CJ and PET(BSD) with NGPDU or NGPDU-4 See LD for details 2334820-3 replaces 2334820-2 PDU control board Used by BSD,HD,VCT, RT,LS,CJ and PET(BSD) with NGPDU or NGPDU-4 Part #: 2334820-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: NGPDU control board FRU: Yes Status: Orderable Comments: 30 Aug 2011 promoted for ECR2122276.305024364
- Area
- CT