GE Healthcare · CTLightSpeedVCT2300230482600074175069014912

LightSpeed 4.X - GRE

Symptom

Circular artifact on scan images. Artifact may look like a donut or have light and dark bands. See Long Description for details Circular artifact on scan images. Artifact may look like a donut

Error message

Error: 230023048 Detector may not be at proper operating temperature to run Fast Cal See Long Description for complete error Wed Jan 18 07:25:50 2006 Error: 230023048 Host: ct99 Process: dailyPrepRx File: DailyPrepShellMgr.c Line: 2159 Detector may not be at proper operating temperature to run Fast Cal.

Error: 260007417 Detector Temperature Is Low. Image quality may be affected See Long Description for full error Wed Jan 18 07:25:21 2006 Error: 260007417 Host: DAS Process: DCB Firmware File: dtemptst.c Line: 373 Function: DATA ACQUISITION : Detector Heater Scan: 50690/1/2 Type: Axial Exception Level: Sec/Soft Time: 07:25:21:605 Log Series: 51 Detector Temperature Is Low. Image quality may be affected. Current Reading:31.54 Deg C A/D Counts:14912

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2323504 Detector assembly See LD for more information Detector assembly p/n 2323504 Part #: 2323504 Part Type: GP REPAIRABLES Part Weight: 0.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: WATSON16 DETECTOR ASM FRU: Yes Status: Orderable Comments: FLS - WATSON16 DETECTOR ASM. THIS PART WILL NOT BE STOCKED BY GPO, WILL NEED TO GET IT FROM CT MANUFACTURING. ADDED PER H16 PROGRAM BY MS20544 ON 7/19/02. PER CT PCN 220726, If your system has 2323504 installed please only order 2323504 and return 2323504 for repair. ms13452 040910
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.