GE Healthcare · CTLightSpeed2600074601281683845157779390451020390451028

LightSpeed 5.X (60kW)

Symptom

"Scan hardware Stopped Scan" with beam tracking errors. "Scan hardware Stopped Scan" with beam tracking errors

Error message

Error: 260007460 Scan ABORT -- Beam Tracking Detected Signal Corruption.^B See LD for complete error Error: 260007460 Host: DAS Process: DCB Firmware File: zaxis.c Line: 1671 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 12816/1/1 Type: Scout Exception Level: Sec/Soft Scan ABORT -- Beam Tracking Detected Signal Corruption.^B mA Level: 5221^B Z Channels : 83845, 157779, 390451020, 390451028^B Offset Vector: 2616853, 2792277, 13958, 14033

Error: 230017814 ACCS CCal: Error: The X's for interpolation must be monotonically increasing or decreasing See LD for complete error Tue Nov 22 07:17:36 2005 Error: 230017814 Host: en_ct_02 Process: accs File: collSweepProcessing.c Line: 2386 ACCS CCal: Error: The X's for interpolation must be monotonically increasing or decreasing: 1632072.625000 1632125.500000 1631534.125000 This could be a transient error. Please retry the scan .

Error: 230017825 The Computed index to the fit region is invalid. Error: 230017825 Host: k2_ct2_ls Process: accs File: collSweepProcessing.c Line: 1142 The Computed index to the fit region is invalid.

Error: 230017801 ACCS CCal: Sweep Processing failed. Status = -1 See the Long Description for the full err

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2404393 GDAS-16 CONVERTOR CARD, replaces 2364354. See Long Description for details. 2404393 GDAS-16 CONVERTER CARD, replaces 2364354 Part #: 2404393 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: 16 SLICE GDAS CONVERTER CARD FRU, A CONVERTER CARD IN AN ESD BAG IN A BOX WITH A PART NUMBER LABEL FRU: Yes Status: Orderable Comments: FLS - 16 SLICE GDAS CONVERTER CARD USED ON: LIGHTSPEED PRO 16 FRU GDAS ADDED PER GDAS RSPL MS13452 040315 RISK: SITE DOWN FREQUENCY: HIGH NOTE: THERE ARE 96 OF THESE CARDS PER SYSTEM, BUT SHOULD NOT NEED TO REPLACE ALL AT ONETIME, MS13452 THIS PART CONTAINS ONE GDAS CONVERTER CARD 2364354 WITH FRU PACKAGING, SUPPLIED BY GEMS IT. MS13452 PDR 8471.80.9000 IM05 UPDATE AWAITING MM (212001261 4/1/06) For 4/8 slice G Das which uses a thick connector must order 2364354-2
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.