LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

No scanning problems noted during smart Prep exam with Error: 200107027 Smart prep diagnostic delay. Expected:5.1 Actual:5.5 Delta:-0.4 See LD for more details. No scanning problems noted during smart Prep exam with Error: 200107027 Smart prep diagnostic delay. Expected:5.1 Actual:5.5 Delta:-0.4 Error: 200107027 is reported to the message log. The following error 200107027 is reported to the gesyslog, this error does NOT interrupt a scan and the technologist is completely unaware the message is placed in the gesyslog. Tue Nov 29 16:04:56 2005 Error: 200107027 Host: vct1 Process: scanRx File: srx_sma_manage_scan.c Line: 4280 Function: Data Acquisition : OC Processing srx_sma_log_smart_prep_diag_delay Smart prep diagnostic delay. Expected:5.1 Actual:5.5 Delta:-0.4

Error message

Error: 200107027 Smart prep diagnostic delay. Expected:5.1 Actual:5.5 Delta:-0.4 See LD for complete error Tue Nov 29 16:04:56 2005 Error: 200107027 Host: vct1 Process: scanRx File: srx_sma_manage_scan.c Line: 4280 Function: Data Acquisition : OC Processing srx_sma_log_smart_prep_diag_delay Smart prep diagnostic delay. Expected:5.1 Actual:5.5 Delta:-0.4

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
05MW31.6 for LightSpeed VCT 7.X with Xtream FX GRE-GOC5 Console Introduced with LS VCT M3A systems produced from Oct 1st, 2005 05MW31.6 VCT 3 disk set 5149029 Includes: - Operating System Disk 5134309 - Application software Disk 5149024 - Serial Over LAN 2399297 Part Number for reference: 31.6 Class C 5149025 31.6 Class M 5149026 5149029 05MW31.6 VCT M3A Collector 3 disk set includes: 5134309 Operating System SW 5149024 Application SW 2399297 SOL Serial Over Lan SW 5149025 05MW31C.6 Class C M3A Proprietary SW 5149026 05MW31M.6 Class M M3A Proprietary SW See list of standard Options
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.