Service Note 43460_0 Aug/03 VGAcq Software Release 6.0
Symptom
Service Note 43460_0 Aug/03 VGAcq Software Release 6.0 Service Note 43460 _0 Aug/03 VGAcq Software Release 6.0 - Updates and Corrections Software 6.0 UGP001351 FMI 40772 Mandatory ITF000143_4 and ITF000160_1 VG/Hawkeye/VH Ver. 6 S/W. Required Prerequisites: FMI 40700, 40707, 40752, 40773 Update 1. Service Pack For 6.0 UGP001509 SN43474 Optional ITF000166 Service Pack Update 2. VG 6.0 SW Patches X-ray artifacts Patch UGP001533 SN43509 Optional ITF000174 Optional X-ray artifacts Patch for 6.0 Update 3. Possible Incorrect Patient Study Archiving, Motion & Worklist patch LSW000426 (Part of (UGP001351) SN43524 Motion & Worklist Patch for 6.0 - LSW000426 (part of UGP001351)
Applies to
- Product
- VGH VG and VG Hawkey and Varicam
- Software
- VGH 6.0 VGH Acq 6.0 VG Acq 6.0 Part #: UGP001355 VG/DVG VER.6 KIT FOR SPARE PART (also see additional requirements below) Includes Software LSW000398 VG DVH HAWKEYE VER. 6 SW PACKAGE: Engineering Bill of Materials Name Description LSW000382 VG VH HAWKEYE Ver. 6 SW CD LSW000312 RCU for Dell 1400SC LSW000332 DISKETTE 1 SYSTEM LSW000403 Ver 6.0 Supplement 12 patch ver 6.0 build 7.5 (SN43633) LSW000426 VG Ver. 6 Motion and Worklist Patch.(SN43524) Also Includes: Software LSW000333 SOFTWARE PACKAGE FOR OLD COMPUTER VG: Engineering Bill of Materials Name Description LSW000011 DISKETTE 1 SYSTEM LSW000203 CKERMIT for GX200 LSW000022 SOFTWARE DELL ECU DISKETTE LSW000101 RCU for DELL 1300 ESW000637 HPC-HP 3COM LSW000404 DISKETTE 1 SYSTEM For HP NetServer Dell 2200 In addition VG requirements : UGP001583 VG Ver. 6.0 MUGA Patch LSW000490, FMI 40788 5195796 VG CoDe 2 Cold Spot, FMI 40805, CODE system only. 5169077 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633 Optional: 5169169 Service Pack # 5169169 Q3 ver 2.0, SN43632
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- FMI 40772 Software Ver. 6.0 for Varicam/Millennium VG, Hawkeye and Discovery VH Systems plus Mechanical Hardware Upgrade
- Nuclear Service Note Listing December 2010 (By Product)
- Nuclear Service Note Listing December 2010 (By Number)
- FMI 40773_2 Apr/03 VGH Improvement to Collimator Exchange Procedure ITF000139_02
- Muga patch FMI 40788 when loaded does not indicate it completed
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR