LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
When loading software, the OC Applications software “The System needs to be rebooted for changes to take effect. Do you wish to reboot now?" GUI does not display. See Long Discription for more Information When loading software, the OC Applications software, the following message (GUI) does not appear “The System needs to be rebooted for changes to take effect. Do you wish to reboot now?" See Step 39 -This is the reboot GUI which does not show-up !! 4.2.2 Application Software Installation on the Host Computer 38. As the system reboots, the following Winterm window message appears: Starting LFW procedure. A shell Installation screen appears and the application software starts loading. 39. When the system prompts you to reboot (after approximately 13 minutes), answer [YES]. The system is going down for reboot NOW. (See illustration, below.) 40. After approximately 3 minutes, a pink pop-up box appears, stating CT Software Auto- Start Disabled. In this box, click [OK]. 41. Press the button on the DVD ROM drive to remove the VCT/Xtream Applications Disk #2 CDROM from the Host Computer. 4.2.3 Setting Time and Date
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required