GE Healthcare · CTLightSpeedVCT260133240
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
A2D Limit Test failed message is reported to the gesyslog during a hardware reset.
Error message
Error: 260133240 A2D Limit Test failed- See error variations See Long Description for full error Fri Jun 22 17:31:33 2007 Error: 260133240 Host: orp Process: orp_subsys File: ADControl.cxx Line: 376 Fri Jun 22 17:31:32 2007 Host : Collimator Ermes # : 260133240 Exception Class : Secondary Severity : Pri/Soft File : ADControl.cxx Line# : 376 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 A2D Limit Test failed for the P5VA channel Value returned from A2D : 988 millavolts Channel upper limit : 5250 millavolts Channel lower limit : 4750 millavolts. Wed Mar 14 12:16:13 2007 Error: 260133240 Host: orp Process: orp_subsys File: ADControl.cxx Line: 286 Wed Mar 14 12:16:13 2007 Host : Collimator Ermes # : 260133240 A2D Limit Test failed for the P48V A channel Value returned from A2D : 1897 millavolts Channel upper limit : 1775 millavolts Channel lower limit : 1605 millavolts.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 05MW31.6 for LightSpeed VCT 7.X with Xtream FX GRE-GOC5 Console Introduced with LS VCT M3A systems produced from Oct 1st, 2005 05MW31.6 VCT 3 disk set 5149029 Includes: - Operating System Disk 5134309 - Application software Disk 5149024 - Serial Over LAN 2399297 Part Number for reference: 31.6 Class C 5149025 31.6 Class M 5149026 5149029 05MW31.6 VCT M3A Collector 3 disk set includes: 5134309 Operating System SW 5149024 Application SW 2399297 SOL Serial Over Lan SW 5149025 05MW31C.6 Class C M3A Proprietary SW 5149026 05MW31M.6 Class M M3A Proprietary SW See list of standard Options
- Area
- CT
Full cause & step-by-step resolution