GE Healthcare · CTLightSpeedVCT2451895240002451772452152910000245047
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Unable to perform scan at certain KV stations
Error message
Error: 245189 A valid calibration module could not be derived from the calibration database. Invalid Calibration Vector: acal, Row: 0. See LD for complete error Tue Oct 11 10:45:52 2005 Error: 245189 Host: er_ct5_vct Process: scanmgr File: scanmgr_lib.cxx Line: 229 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 524000 A valid calibration module could not be derived from the calibration database. Invalid Calibration Vector: acal, Row: 0. Error: 245177 An Acquition Complete event was recieved when Scan Manager was not in a scanning state. See LD for complete error Tue Oct 11 10:45:52 2005 Error: 245177 Host: er_ct5_vct Process: scanmgr File: scanmgr_events.cxx Line: 3531 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 524000 An Acquition Complete event was recieved when Scan Manager was not in a scanning state. Acq Complete Sequence Number: 524000 Error: 245215 Scan setup failed on Step:7 (Get Cal Module). Status:-1 See Long Description for complete error Tue Oct 11 10:45:52 2005 Error: 245215 Host: er_ct5_vct Process: scanmgr File: scanmgr_lib.cxx Line: 1224 Function: System Control : Scan Control Scan Type: Axia
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 05MW31.6 for LightSpeed VCT 7.X with Xtream FX GRE-GOC5 Console Introduced with LS VCT M3A systems produced from Oct 1st, 2005 05MW31.6 VCT 3 disk set 5149029 Includes: - Operating System Disk 5134309 - Application software Disk 5149024 - Serial Over LAN 2399297 Part Number for reference: 31.6 Class C 5149025 31.6 Class M 5149026 5149029 05MW31.6 VCT M3A Collector 3 disk set includes: 5134309 Operating System SW 5149024 Application SW 2399297 SOL Serial Over Lan SW 5149025 05MW31C.6 Class C M3A Proprietary SW 5149026 05MW31M.6 Class M M3A Proprietary SW See list of standard Options
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.