GE Healthcare · Nuclear MedicineMillennium2433129398295552986629944
Service Note 43570_B Dec/04 Patch GA400-2-1 for GenieAcq Software Release 4.0
Symptom
Service Note 43570_B Dec/04 Patch GA400-2-1 for GenieAcq Software Release 4.0 Service Note 43570 _B Dec/04 Patch GA400-2-1 for GenieAcq Software Release 4.0 Corrections Patch GA400-2-1 needs to be installed on all SW Version R4.0 Vo18 M3 Version systems Spare Part UGP001609 Update 1. Genieacq Patch GA400-02-1 fails to load from Single user mode as instructed.
Error message
Error message "Failed to archive things being patched. Exiting" while loading Genieacq Patch GA400-02-1 (SN43570) If you see this message while loading the patch, that means you loaded it from the single singn on, i.e. you used b - tar: can't add file /ppget: File or directory does not exist tar: can't add file/ppupdate.ui: File or directory does not exist Failed to archive things being patched. Exiting For SN43570, While loading Patch: GA400-02-1 If you see this message shown below while loading the patch, that means you loaded it from the single singn on, i.e. you used b - Extracting Patch from GA400-02-1 Reading the patch descriptor Patch: GA400-02-1 R.40 V018 cumulative fixes Elgems 24331 .... Elgems 29398 .... Elgems 29555 .... Elgems 29866 .... Elgems 29944 .... tar: can't add file /ppget: File or directory does not exist tar: can't add file/ppupdate.ui: File or directory does not exist Failed to archive things being patched. Exiting Do not load this patch from the single user login, it will not work. The service note instructions are bogus. Once you have made this mistake you will need to remove the files that were loaded, then reload the patch from the service login, open a
Applies to
- Models
- Millennium
- Product
- MG/MC/Myosight Millennium MG/MC Millennium MyoSIGHT IBACQ/X IBACQ/X IBACQ/X MPR/MPS Millennium MPR Millennium MPS
- Software
- Genieacq 4.0 Genieacq 4.0
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- How do I capture and print COR and Camera Uniformity (CUA) result screens on Genieacq, then send to a processing station for ACR
- Collision and E-stop lights are red on the back of the gantry and no movement with Hand Held Controller (HHC) or the genieacq.
- Need part numbers for the Millennium MG/MC table E-Stop
- How do I Delete a file on Genieacq that the system thinks is still acquiring
- VG, the contour works... but in the opposite way.
- MG_MC_MyoSight_MPR_MPS Bar Phantom Resolution Size