Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT260122028

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Can't perform fastcal. Detector Rail Temperature Out Of Range

Error message

Error: 260122028--Heater thermal sensor returning unreasonable value. See long description for full error detail. Sat Dec 18 11:11:56 2010 Host : tgp Proc : tgp_subsys Error : 260122028 File : gantryThermalMgr.cxx Line: 569 Sat Dec 18 11:11:56 2010 Host : Table Gantry Processor Ermes # : 260122028 Exception Class : Secondary Severity : Pri/Soft File : gantryThermalMgr.cxx Line# : 569 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Heater thermal sensor returning unreasonable value. Temperature 4050 is considered a partial SHORT (Temperature is in 1/100th degree C)

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5261028 (replaces p/n 5129987) Low CH Thermostat asm RoHS See long description Part #: 5261028 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Low CH Thermostat asm RoHS FRU: Yes Status: Orderable Comments: added per to ECR2056498 by sso#305010201 in Nov 21, 2008
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues